Ultrasonic
vibratory separator is the organic combination of ultrasonic controller and vibrating screen, translate the 220V, 50HZ or 110V, 60HZ electrical energy into 18KHZ high-frequency electrical energy, input ultrasonic transducer, change it into 15KHZ mechanical vibration, so as to achieve the purpose of screening and cleaning the mesh. A high frequency and low amplitude ultrasonic vibration wave is superimposed on the screen, and the ultrafine powder receives tremendous ultrasonic acceleration, which makes the material on the screen in suspension, so as to inhibit adhesion, friction and other factors blocking the mesh. Thus, it can effectively solve the screening problems and it is no longer difficult to screen ultrafine fine powder, especially suitable for high quality and fine separation users.
The advantages of ultrasonic vibratory separator
1.High efficiency, exquisite design and durable, any powder particles of irregular shape can be sifted;
2.The screen is installed with a mesh cleaning device, which can solve the problem of blocking effectively;
3.There is no mesh blockage and dust fly phenomenon;
4.Impurities and coarse materials are automatically discharged, can be continuous operation;
5.Unique mesh design,long service time of screen mesh. It takes only 3-5 minutes to change the mesh.
The common failures and solutions of ultrasonic
vibratory separator
1.The motor can be replaced when the motor is damaged;
2.Electrical components can be replaced when electrical components in the control line are damaged;
3.The voltage is insufficient and the method of changing the power supply can be adopted;
4.The method of cleaning material on the screen can be adopted when the material accumulates too much;
5.If the vibrator is out of order, the method of overhauling the vibrator can be adopted;
6.When the grease in the vibrator thickens and agglomerates, the method of cleaning the vibrator and adding the suitable grease;
7.When the ultrasonic controller can not work normally, check whether the parts of the connection is tight, if found loose, tighten it.
The common failures and solutions of ultrasonic screening system
1. Ultrasonic vibration power supply does not display, ultrasonic device does not work, should check whether the 220V power line is broken, if there are problems, please timely repair and replace. Check the safety pipe of ultrasonic vibration power supply. If it burns out, please replace it with the power supply bogie switch. If there is any problem, please replace it;
2. When the ultrasonic power supply appears continuous or intermittent sound, check the connection between the ultrasonic shaker power supply and the transducer, if there is a circuit, please replace. Check the connector plug for water, damp or conductive material. If there is a short circuit, repair and check in time. Check the insulation value of the cable and plug. If the resistance is less than 1MQ, please replace the plug.Check whether the transducer is locked or not. If the fault cannot be eliminated after all inspections, please return to the factory for repair;
3. The power supply amplitude of ultrasonic
vibratory separator is small, the amplitude of the screen is weak, check the insulation value of the cable and plug. Checking the transducer, if the transducer is not locked, tighten the transducer with a large wrench. Checking whether the screen is tight, whether there is open glue, if have, please tighten the screen or the stretching screen. Checking whether there is any dirt between the transducer and the pedestal of the frame. If there is, please clear the sundries between the pedestals. Checking the resonator or rods for cracks causing frequency misalignment.